Hot tub error codes, you may need to identify your spa pack brand first. Different spa packs and spa brands have their own set of error codes, but two commonly used are Balboa Error Codes and Gecko Error Codes. It's important to note that Balboa Error Codes are applicable to all circuit boards manufactured by Balboa, even those customized for brands like Cal Spas, Marquis Spas, Master Spas, Jacuzzi, Sundance, and more.
Balboa Error Codes
- pd: Power supply on battery
- OH: Sensors reading 112-118F
- OHH: Overheat. One sensor has detected 118º. Spa has shut down.
- OHS: Overheat.. One sensor has detected 110º. Spa has shut down.
- Flo: flow/pressure switch error
- Cool: Water temp 20 degrees below set point
- ICE: Potential freeze condition
- Sn1: Hi-limit sensor failure
- Sn3: Temp sensor malfunction
- Sna: Sensor A fail
- Snb: Sensor B fail
- SnS: Sensors out of balance. If alternating with temp, may be temporary condition.
- HFL: Substantial difference between temp sensors detected. Could indicate a flow problem
- LF: Persistent low flow problems. (Displays on the 5th occurrence of "HFL" message with 24 hours). Heater is shut down, but other spa functions run normally.
- dr: Inadequate flow in heater.
- dry: Inadequate flow in heater. (Displays on third occurrence of "dr" message)
- Pr: When spa is first actuated, it will go into Priming Mode
- ---: Unknown water temp.
- Std: Spa operating in Standard Mode.
- Ecn: Spa operating in Economy Mode.
- SE: Spa operating in Standard-in-Economy Mode.
- ILOC: Interlock failure - possible pump/ozone spike
CTI Error Codes
- thl/39: temp probe problem
- th2/current temp: temp probe problem
- th3/39: water temp below 39° F
- OH: water over 112° F. System will restart when temp. drops
- hot: water over 112° F. System will restart when temp. drops
- HL: High limit switch tripped
Dream Maker Error Codes
- OH: Overheat 108° F, spa is deactivated.
- FL: Flow. Pressure switch not working
- SN: Non functional high temperature sensor. Heater is deactivated
- F2: 4 hours daily filtration
- F4: 8 hours daily filtration
- F6 : 12 hours daily filtration
- FC : continuous filtration
EasyPak Error Codes
- C: Celsius
- CL: Current Time of Day
- ECdu: Econo Mode Duration
- Econ: Econo Mode Turn On
- F: Fahrenheit
- Fldu: Filter Cycle Duration
- Flon: Filter Cycle Turn On
- FLC: Pressure Switch Alarm
- FLO: Pressure Switch Alarm
- FrEE: Freeze Protection Alarm
- HL: High Temperature Alarm
- Loc: Panel / Keypad Locked
- PrH: Temperature Sensors Alarm
- Prr: Temperature Sensors Alarm
- Tu: Temp Set Celsius
- Tu: Temp Set F
Gecko S-Class & M-Class
- AOH: Temp in Equipment compartment to high
- FLO: Pressure switch failure, switch open
- FLC: Pressure switch failure, switch closed
- FrE: Possible freeze condition
- 3 Flashing Dots: Flow error
- 3 Flashing Dots & LED
- HL: Sensor measuring 119F
- Prr: Temp sensor failure
- Prh: Hi-limit sensor failure
Gecko SP Codes (Spa Packs)
- SP-HR: hardware error
- SP-BR: breaker setting to low
- SP-IN: Input voltage low
- SP-F1,F2 or F3: Fuse 1,2 or blown
- SP-OT: Temp inside skirt high
- SP-OH: Water temp over 112F
Gecko RH Codes (Heater)
- RH-HR: Heater Hardware error
- RH-NH: Heat attempted & failed
- RH-NF: No flow in heater
- RH-NC: Comm error to Pack
- RH-HL: Heater Hi Limit
Gecko Accessory Codes
- P1, P2 or P3-ER: Pump 1,2 or 3 failure
- CP-ER: Circ pump failure
- BL-ER: Blower failure
- O3-Er: Ozone error
- A1/A2-ER: Aux. system error
- FN-ER: Fan failure
- FB-ER: Fiber optic failure
- SC-ER: System learning failure
Jacuzzi Error Codes
- OH : Overheat Protection (Heater is deactivated, pumps low speed is activated)
- COOL : temp 20° F cooler than set point
- FLO* : Flow Switch (heater is deactivated. Pump may also be deactivated)
- FLO2 : Closed or shorted flow switch on system startup
- Hold : Panel pressed too many times in a short period of time
- HOT : Circuit Board temp exceeded acceptable limit
- ICE : Freeze protection.No action is necessary
- I CE2 : Freeze protection.No action is necessary
- PnL : Communication error between the panel and circuit board
- ---- : "Watchdog" problem detected
- Sn1 : Open/Shorted sensor
- Sn3 : Open /shorted sensor FLO2: Closed/shorted flow switch at startup
Pinnacle Spas Error Codes
- OH: Temperature has exceeded 110° F
- SN: Sensor failure
- FL: Flow/pressure switch stuck in closed position
Spa Builders By Gecko Error Codes
- Sn1: Nonfunctional high temp sensor.
- Sn2: Nonfunctional temp sensor.
- FL1: Water flow problem, pressure switch malfunction. Check for low water level and ensure pump is primed. Check for clogged filter
- FL2: Pressure switch problem. Switch closed while pump is deactivated
- COL: Cool condition. If water temp drops 20ºF below set temp, low speed pump and heater activates to bring temp within 15º of set temp
- ICE: Freeze condition. 55ºF detected. Low speed pump and heater will activate until spa reaches 65ºF
- OH: High temperature condition, has reached 110ºF. Low speed pump (and air blower if equipped) will activate to lower temp
- ---: "Watchdog". Water temp has reached 118ºF.
Spa Quip Error Codes
- err 1 (H20) : Prime Failed
- err 3: Stuck Button
- err 4 : No Water Sensor
- err 5 : Over temp
- err 6 : Thermal Cut Out Tripped
- err 7 : Stuck Relay
- err 8 : No Temp Data
- 01: Stuck Button
- 02: No Controller Data
- 03: Temp Sensor
- 04: Water Sensor
- 05: Spa Over Temp
- 06: Heater Thermal Cut Out
- 07: Stuck Heater Relay
- 09: Water Prime Failed
Sundance Spas Error Codes
- COL: Temp 20F below set point
- ILOC: Interlock failure - possible pump/ozone spike
- FLO/FL1/FL2: Flow/Pressure switch malfunction
- Hold: Panel buttons pressed to many times/quickly
- HOT: PCB temperature above acceptable limit - air blower on
- ICE: Potential freeze condition
- Pnl: Communication between PCB and panel interrupted
- Sn1: Hi-limit sensor failure
- Sn3: Temp sensor failure
- ---: "Watchdog" problem detected (possible temp /hi-limit error)
Vita Spas Error Codes
- HiLi: Water tem over acceptable limit
- BJ2P: Pump/Blower purge - normal condition
- FP: Freeze protect mode - temp under acceptable condition
- SS=0;SS=S;LS=O;LS=S : Multiple causes; open sensors, bad connection or voltage
When and how will my order ship?
Orders placed before 10am EST Monday to Friday excluding holidays typically ship same day for items in stock at one of our shipping facilities. Most orders leave the warehouse within 48 hours during business days. If item(s) on your order are back ordered or sold out before your order can be filled, a follow up email will be sent to you. Any orders with Special Order items will ship when the Special Order items arrive at the shipping depot.
Once your order has shipped the tracking information will be included in your Shipping Confirmation email. Please note that it can take up to 48 hours for the shipping company to update online tracking information. We ship using multiple delivery partners including Canada Post Expedited Parcel, UPS, and Purolator. Orders with a PO Box or Rural Route address ship via Canada Post only. Items may be shipped from multiple locations and arrive in separate packages and on different days.
Free Ground Shipping
Free shipping is available on orders of $69 before tax to most locations in Canada, excluding Nunavut, Yukon, Northwest Territories, remote/beyond zones. Pool & Hot Tub Depot will select the most cost-effective carrier for orders eligible for free shipping to your area, typically Canada Post Expedited ground shipping. Alternative shipping options are available at checkout for an additional fee.
$9.00 Flat Rate Standard Ground Shipping
$9.00 Flat rate standard ground shipping is available on orders under $69 before tax to most locations in Canada, excluding Nunavut, Yukon, Northwest Territories, remote/beyond zones. Pool & Hot Tub Depot will choose the most economical carrier for orders under $69 before tax that have paid the $9 flat-rate shipping fee, usually Canada Post Expedited Ground. Other shipping options can be selected at checkout for an extra cost.
UPS Standard Shipping
UPS Standard is a cost-effective, reliable ground shipping option, available for an additional fee at checkout to select areas in Canada that UPS serves. Please note that the transit time for the package is tracked by UPS starting from the day the order is picked up at the warehouse in London, Ontario, not from the day the order is placed online or by phone. UPS delivery business days are Monday to Friday 9am up to 8pm. All Canadian holidays are excluded and do not count as a business day.
UPS Express Shipping
UPS next business day* delivery is available for an additional fee at checkout to select areas in Canada that UPS serves. Please note that the transit time for the package is tracked by UPS starting from the day the order is picked up at the warehouse in London, Ontario, not from the day the order is placed online or by phone. *UPS delivery business days are Monday to Friday 9am up to 8pm. All Canadian holidays are excluded and do not count as a business day.
In-Store Pickup
In-store pickup is available at the London, Ontario location only. You will be notified via email when your order is available for pick-up. Please wait for the email as your order may not be available for pick up earlier. Orders that have not been picked up within 30 days of the order date may be cancelled and refunded to the original method of payment.
Remote and Airstage Locations
As determined by Canada Post and or UPS, areas considered remote, that receive infrequent mail service or where mail must be airlifted are ineligible for free shipping or $9.00 flat rate shipping. Remote areas are listed in Table 9 and the Air Stage Locations list is available here. Shipping costs to any of these areas is calculated by weight and size of the order, please add the desired items to the cart and enter your postal code in the shipping calculator of the shopping cart.
Shipping Outside Canada
Poolandhottubdepot.com only ships within Canada. Unfortunately we are not able to export our products to any other countries.
Cancellations
Should the need arise to cancel an order after it’s been placed, we will do our best to accommodate your request. Please get in touch with our Customer Care team as soon as possible, ways to contact us can be found here. Once your order moves into the awaiting shipment stage in our warehouse, we may no longer be able to cancel it. Should this be the case, we can help facilitate a return upon delivery (excluding final sale items).